OEM P/N:
ESCT P/N:
PART TYPE:
OEM:
The CEL CL380-364-0.5(PH)V2 is a silicon cathode electrode used in Tokyo Electron (TEL) 300 mm capacitively coupled plasma (CCP) etch process chambers. As a cathode-class consumable, it forms one of the powered or grounded electrode surfaces that bound the plasma, directly facing the discharge and bearing the brunt of continuous ion bombardment. The “CEL” designation and the cathode part type identify this as a machined high-purity silicon electrode body rather than a quartz, ceramic or aluminium hardware item, and the “(PH)” and “V2” suffixes denote a specific surface/phosphorus-doped variant and a second-revision geometry within the CL380 family.
Positioned at the boundary of the etch reaction volume, the cathode electrode establishes the electric field that accelerates ions toward the wafer or that defines the counter-electrode reference, depending on the chamber architecture. Because it is silicon, it is chemically compatible with fluorine- and chlorine-based etch chemistries and is intentionally consumable: the surface is sacrificially eroded so that the process environment remains clean, predictable and free of metallic contamination. The 0.5 dimensional code and the doping/finish callouts make this a process-matched item, resistivity, thickness and flatness all influence how the plasma couples to the wafer.
Within a fab, the cathode electrode is one of the parts that most directly governs etch rate stability, within-wafer uniformity and particle performance. As it erodes over its service life, the chamber drifts; replacing it on schedule with a correctly specified, dimensionally faithful part is therefore a routine but high-leverage element of preventive maintenance.
The cathode electrode is an active participant in plasma generation, not merely a structural surface. In a CCP etch chamber it works together with the opposing electrode, the RF delivery network and the gas distribution hardware to create and shape the discharge that performs the etch. Its principal functions include:
The electrode is machined from high-purity silicon, with the phosphorus-doped (PH) variant selected to deliver a controlled electrical resistivity. Resistivity matters because the cathode must conduct RF current while remaining electrically consistent across its area; an out-of-specification material shifts power coupling and can change etch rate and selectivity.
The plasma-facing surface and overall flatness are as important as the bulk material. Surface texture influences sheath stability and particle generation, while thickness and flatness define the electrode gap and therefore field uniformity. The V2 revision geometry must be reproduced faithfully so that fit and process behaviour match the installed base.
Because the cathode electrode sits at the heart of the discharge, its condition propagates directly into wafer-level results. A correctly specified, fresh electrode supports stable, in-spec processing; a worn, contaminated or mismatched part erodes both etch performance and yield. Key consequences include:
Continuous ion bombardment sputters and etches the silicon surface over time. As the electrode thins, the electrode gap changes and sheath geometry shifts, producing gradual process drift that eventually pushes the chamber out of specification and signals end of useful life.
Localised hot spots, micro-arcing and thermal cycling can roughen, pit or crack the silicon. A degraded surface becomes a particle source, raising defect counts on the wafer, and in severe cases mechanical cracking can occur, demanding immediate replacement.
Erosion or contamination at mounting and contact interfaces increases contact resistance and disturbs the RF return path. The result is unstable impedance matching, rising reflected power and inconsistent delivered energy, all of which destabilise the etch process.
Replacement should follow the relevant TEL preventive-maintenance procedure for the specific chamber, observing all electrostatic-discharge, vacuum and contamination-control practices. The following sequence outlines good practice:
Silicon cathode electrodes are scheduled consumables, so hold a verified spare to avoid chamber downtime when a part reaches end of life. ESCT Fab Support supplies the CL380-364 electrode as a cost-effective, quality-controlled alternative to single-sourcing through the OEM, with the following advantages:
It is a silicon cathode electrode that forms a plasma-facing boundary of the discharge in a TEL 300 mm CCP etch chamber. It helps establish the electric field, carries RF current, participates chemically in the etch and erodes sacrificially to keep the process clean.
No. This is a second-source new part, supplied as a new OEM-compatible component verified to form, fit and function against OEM P/N 2L10-250520-11. It is not an original TEL OEM part and is not sold as one.
Silicon is chemically compatible with fluorine- and chlorine-based etch chemistries, erodes to benign species rather than contaminating the wafer with metals, and helps balance radical and polymer behaviour. Its controlled resistivity also lets it serve as an electrical electrode.
Indicators include measurable etch rate or uniformity drift, rising particle counts, unstable RF matching and visible surface erosion, pitting or thinning. Most fabs replace the electrode at a defined RF-hour interval set by their qualification data.
(PH) denotes the phosphorus-doped material/finish variant used to set the electrode’s resistivity, and V2 indicates the second-revision geometry within the CL380-364 family. Matching both means the spare behaves identically to the installed part.
Typical lead time is 4–5 weeks. Because the electrode is a scheduled consumable, we recommend holding at least one verified spare per active chamber and reordering against your preventive-maintenance calendar to avoid unplanned downtime.
The CL380-364-0.5(PH)V2 silicon cathode electrode (ESCT P/N ES7099-109, OEM P/N 2L10-250520-11) is a plasma-facing cathode consumable for TEL 300 mm capacitively coupled etch chambers. It shapes the plasma field, carries RF current, participates in the etch chemistry and erodes sacrificially to protect process cleanliness. Its high-purity, phosphorus-doped silicon, controlled surface finish and faithful V2 geometry make it a yield-critical part whose timely replacement keeps etch rate, uniformity and particle performance in specification. Supplied by ESCT Fab Support as a verified second-source new part with a 4–5 week lead time, it offers fabs a dependable, cost-effective route to keeping chambers running.
Disclaimer: This part is supplied by ESCT Fab Support as a new, OEM-compatible second-source component, verified to the form, fit and function of Tokyo Electron part number 2L10-250520-11. It is not an original OEM part and is not sold as one. It is not manufactured by, endorsed by, or affiliated with Tokyo Electron, and all manufacturer names and part numbers are quoted for identification and compatibility purposes only.
Fill out the form below to request a quote for the part/s you require, making sure to include the OEM part number.
If the part you are looking for is not listed, get in touch and we will try to source it for you through our wide network of partners and suppliers.
We use cookies We use analytics cookies to see how visitors use this site, so we can improve it. They are set only if you accept. Read our Cookie Policy.