ELECTRODE

PART DETAILS

3D10-250316-11(S)
ELECTRODE

OEM P/N: 

3D10-250316-11(S)

ESCT P/N: 

ES7099-016

PART TYPE:

2nd Source NEW

OEM: 

TEL
MORE INFO

TEL cathode electrode (OEM P/N 3D10-250316-11(S)), silicon RF cathode for TEL 300 mm plasma etch systems

ESCT P/N ES7099-016, 2nd source NEW cathode electrode for Tokyo Electron 300 mm etch process chambers

The TEL Cathode Electrode (OEM P/N 3D10-250316-11(S)) is a powered electrode assembly used in Tokyo Electron (TEL) 300 mm plasma etch process chambers. Within the chamber stack it forms part of the lower electrode architecture, where it couples radio-frequency (RF) power into the discharge and helps establish the plasma sheath that drives directional ion etching of the wafer edge and surface. As a cathode, it is one of the most electrically active surfaces in the chamber, and its condition has a direct bearing on plasma density, sheath voltage and the uniformity of the etch result across a full 300 mm wafer.

Cathode electrodes of this type sit in the high-flux region of the discharge, directly exposed to ion bombardment and reactive radicals. They are typically fabricated from high-purity silicon or silicon-based material so that any sputtered or eroded product is process-compatible rather than a metallic contaminant. The electrode works in concert with focus rings, edge rings and the surrounding insulator hardware to confine the plasma, shape the electric field at the wafer edge and provide a controlled RF return path back to chamber ground.

Because it carries RF current and defines a critical plasma-facing boundary, the cathode electrode is a scheduled consumable. As it erodes, the gap geometry, capacitive coupling and edge field all drift, which is why fabs track it as a preventive-maintenance item and replace it on a defined interval. The ESCT P/N ES7099-016 is offered as a form-, fit- and function-matched replacement so that this maintenance can be carried out without waiting on extended OEM lead times.

Functional role of the cathode electrode in TEL 300 mm etch platforms

The cathode electrode is far more than a passive plate. It is an active component of the RF delivery network and a primary plasma-facing boundary that defines how energy reaches the wafer. Its main functions in a TEL 300 mm etch chamber include:

  • Coupling RF power into the discharge to sustain the plasma and set the sheath voltage that accelerates ions toward the wafer.
  • Establishing a uniform electric field across the electrode surface so that ion flux and etch rate are even from wafer centre to edge.
  • Providing a low-impedance RF return path in conjunction with grounded chamber hardware, stabilising impedance match and reflected power.
  • Acting as a sacrificial, process-compatible silicon surface so that erosion products do not introduce metallic contamination.
  • Working with focus rings and confinement hardware to shape the plasma boundary and control edge etch behaviour.
  • Maintaining a defined electrode gap and surface profile that the process recipe is tuned around.

Material and process performance

Material construction and purity

Cathode electrodes for TEL 300 mm etch chambers are manufactured from high-purity silicon-based material selected for both its electrical behaviour and its compatibility with fluorine- and chlorine-bearing etch chemistries. Material specification matters because the electrode is consumed during normal operation, and what it sputters becomes part of the chamber environment.

  • High-purity silicon minimises metallic contamination and keeps defectivity low on the wafer.
  • Controlled resistivity supports consistent and repeatable RF coupling across the electrode area.
  • Tight flatness and surface-finish control preserve the intended electrode gap and field uniformity.
  • Process-compatible erosion behaviour avoids introducing foreign species into the etch chemistry.

Plasma exposure and erosion resistance

In service the electrode endures continuous ion bombardment, thermal cycling and chemical attack. Its ability to wear predictably (rather than crack, pit or delaminate) is what allows fabs to schedule replacement with confidence and keep process drift within tolerance between maintenance events.

  • Uniform sputter erosion that preserves surface flatness over the service life.
  • Resistance to thermal-stress cracking under repeated plasma on/off cycling.
  • Stable surface chemistry that limits polymer build-up and particle generation.
  • Predictable thinning rate that supports reliable preventive-maintenance scheduling.

Impact on tool performance and yield

Because the cathode electrode sits at the heart of the RF and plasma-shaping system, its condition propagates directly into wafer-level results. A worn, contaminated or out-of-spec electrode does not fail silently, it shows up as measurable process drift and yield loss:

  • Etch-rate drift and shifting endpoint behaviour as electrode thickness and gap change.
  • Degraded within-wafer and wafer-to-wafer uniformity, especially toward the wafer edge.
  • Unstable RF match and rising reflected power, affecting plasma stability.
  • Increased particle counts and defectivity from cracking, flaking or polymer release.
  • Critical-dimension and profile excursions that push lots out of specification.
  • Unplanned downtime and scrap if degradation is not caught at the scheduled interval.

Common wear and failure modes

Sputter erosion and thinning

The dominant wear mechanism is gradual sputter erosion from ion bombardment. As the electrode thins, the electrode gap and capacitive coupling shift, slowly moving etch rate and uniformity away from the qualified baseline until the part reaches its replacement limit.

Thermal-stress cracking and chipping

Repeated thermal cycling combined with the brittleness of silicon-based material can lead to micro-cracking, edge chipping or fracture, particularly if the part is mishandled during installation. Cracks compromise both electrical performance and mechanical integrity and are a frequent source of particles.

Surface contamination and polymer build-up

Reactive etch by-products can deposit on the electrode surface as polymer or residue films. These deposits alter local impedance and surface chemistry, can flake off as defects, and degrade the consistency of RF coupling if the electrode is run beyond its intended service window.

Installation and replacement guidance

Replacement should be performed by trained technicians following TEL maintenance procedures for the specific chamber. The silicon electrode is brittle and an RF-critical surface, so keep it clean and handle it carefully. A typical sequence is:

  • Vent the chamber, lock out RF and gas supplies, and allow the hardware to cool to a safe temperature before opening.
  • Remove surrounding focus rings, edge rings and confinement hardware needed to access the electrode, noting their order and orientation.
  • Detach the worn cathode electrode and inspect mating surfaces, fasteners and RF contact interfaces for residue or damage.
  • Clean the seating area per TEL procedure so that electrical contact and the electrode gap are restored to specification.
  • Fit the new ES7099-016 electrode using clean, gloved handling, seating it evenly and torquing fasteners to the specified values.
  • Reinstall the rings and confinement hardware, then pump down, leak-check and season or condition the chamber as required.
  • Run RF match verification and process qualification wafers to confirm uniformity and etch rate before returning the tool to production.

Spare parts strategy for TEL 300 mm etch fleets

Cathode electrodes are recurring consumables, so a dependable second-source supply is central to keeping etch tools available and process windows stable. ESCT Fab Support supplies the ES7099-016 cathode electrode as a cost-effective alternative to sole-source procurement, with benefits including:

  • Form-, fit- and function-matched to OEM P/N 3D10-250316-11(S) for direct replacement.
  • 2nd Source NEW condition, supplied ready for installation.
  • A defined 4-5 week lead time that supports planned preventive-maintenance scheduling.
  • Reduced dependence on a single supply channel, improving spares resilience.
  • Competitive pricing to help control consumable spend across a tool fleet.
  • Clear cross-reference between ESCT P/N ES7099-016 and the OEM number for straightforward ordering.

Frequently asked questions

What does this cathode electrode do in the chamber?

It is the powered (cathode) electrode that couples RF energy into the plasma and helps set the sheath voltage that drives directional ion etching. It also acts as a process-compatible plasma-facing surface and part of the RF return system, so its condition strongly influences etch rate, uniformity and plasma stability.

Is this an original OEM part?

No. ESCT P/N ES7099-016 is supplied as a new, OEM-compatible cathode electrode that is verified to the form, fit and function of OEM P/N 3D10-250316-11(S). It is not an original Tokyo Electron part and is not sold as one; it is offered as a second-source alternative for fabs seeking supply flexibility.

What material is the electrode made from?

It is manufactured from high-purity silicon-based material chosen for controlled resistivity, compatibility with fluorine- and chlorine-based etch chemistries, and process-compatible erosion so that wear products do not introduce metallic contamination onto the wafer.

How do I know when it needs replacing?

Replacement is usually driven by a preventive-maintenance interval based on accumulated RF hours or wafer count, supported by inspection. Drifting etch rate or uniformity, rising reflected power, increased particle counts, or visible thinning, cracking or contamination are all signs the electrode has reached the end of its useful service window.

What is the lead time for ES7099-016?

The current lead time is 4-5 weeks. Because cathode electrodes are recurring consumables, we recommend aligning orders with your preventive-maintenance plan and holding appropriate safety stock so a tool is never held up waiting on a spare.

Does fitting a second-source electrode require requalification?

Any plasma-facing RF component should be qualified after installation. As with an OEM replacement, the recommended practice is to run RF match verification and process qualification wafers, confirming etch rate, uniformity and particle performance before returning the tool to production.

Summary

The TEL Cathode Electrode (OEM P/N 3D10-250316-11(S)), supplied by ESCT Fab Support as P/N ES7099-016, is a high-purity silicon RF cathode for Tokyo Electron 300 mm plasma etch chambers. It couples RF power into the discharge, shapes the plasma sheath and serves as a process-compatible plasma-facing surface, making it central to etch rate, uniformity and particle performance. As a scheduled consumable subject to sputter erosion, thermal cracking and surface contamination, it benefits from a reliable second-source supply. Offered in 2nd Source NEW condition with a 4-5 week lead time and a clear OEM cross-reference, ES7099-016 helps fabs sustain etch-tool uptime and stable process windows without sole-source dependency.

Disclaimer: This part is supplied by ESCT Fab Support as a new, OEM-compatible second-source component, verified to the form, fit and function of Tokyo Electron part number 3D10-250316-11(S). It is not an original OEM part and is not sold as one. It is not manufactured by, endorsed by, or affiliated with Tokyo Electron, and all manufacturer names and part numbers are quoted for identification and compatibility purposes only.

REQUEST A QUOTE

Fill out the form below to request a quote for the part/s you require, making sure to include the OEM part number.