OEM P/N:
ESCT P/N:
PART TYPE:
OEM:
The Core Inner Electrode is the central silicon cathode element that sits at the heart of the lower powered assembly in a 300 mm plasma etch chamber. Positioned directly beneath or surrounding the wafer support, the inner electrode forms the innermost zone of the RF-driven cathode stack and establishes the baseline electric field that ignites and sustains the plasma sheath above the wafer. Because it occupies the very centre of the powered surface, its condition has a disproportionate effect on the uniformity, repeatability and particle performance of every wafer processed through the tool.
In the LAM family of high-density etch platforms, the cathode is built up from concentric silicon and ceramic parts that together define the coupling area, the RF return path and the thermal profile of the chuck. The Core Inner Electrode is the consumable that lives closest to the active plasma, taking the most intense ion bombardment and the highest local power density. As an exposed silicon surface it is also chemically and physically consumed over time, which is why it is treated as a scheduled replacement item rather than a permanent structural part.
ESCT Fab Support offers this component, ES2099-051, as a second-source new alternative to the original LAM 716-069688-005. It is manufactured and inspected to match the form, fit and function of the OEM electrode so that process engineers can hold a critical wear part on the shelf without depending on a single supply chain. The lead time on this item is typically 4–5 weeks.
The inner electrode is far more than a passive plate. It is an active part of the RF circuit, the thermal management system and the gas/field geometry that together determine how the plasma behaves across the centre of the wafer. Its principal functions include:
Inner electrodes of this type are produced from high-purity, controlled-resistivity silicon. The resistivity and dopant level are specified deliberately, because the electrode must conduct RF efficiently while still behaving as a silicon surface in the plasma chemistry. Surface finish, flatness and edge profile are equally important: a tightly controlled finish minimises field concentration points and gives a predictable consumption rate. The bulk silicon must be free of micro-cracks and inclusions that could nucleate fracture or shed particles under cyclic thermal and ion loading.
During processing the electrode endures fluorine- and chlorine-based chemistries, energetic ion bombardment and steep thermal gradients between the plasma-facing surface and the cooled body below. The part is engineered to consume evenly under these conditions so that its electrical and field-shaping behaviour drifts slowly and predictably rather than abruptly. Even erosion is what allows a fab to qualify a fixed replacement interval and keep etch rate and profile stable across the life of the part.
Because the inner electrode controls the centre of the powered surface, its condition feeds directly into the metrics that fabs watch most closely. A worn, contaminated or mis-seated electrode shows up quickly in process data and in wafer results:
The dominant wear mode is gradual consumption of the silicon by ion bombardment and chemical attack. As the central surface thins, the cathode gap and local field strength change, slowly altering centre etch behaviour. Past a recipe-dependent threshold the part can no longer hold the process within its uniformity window and must be replaced even though it remains physically intact.
Repeated thermal cycling, localised hot spots or mechanical over-clamping can initiate cracks in the silicon. These compromise the RF path, become strong particle sources and, in the worst case, lead to a fractured electrode that scatters debris into the chamber. Careful handling and correct torque during installation are the main defences against this failure mode.
Polymer build-up, redeposited films or a degraded contact interface between the electrode and the cathode body raise contact resistance and disturb both heat transfer and RF return. This shows up as temperature non-uniformity, arcing or erratic tuning, and is often the trigger for a chamber clean or an early electrode swap.
Replacing the Core Inner Electrode is a precision task performed during scheduled preventive maintenance. The following sequence reflects general good practice; always defer to your site procedures and the LAM maintenance documentation for the specific platform.
Cathode silicon is a recurring, high-impact consumable, so a sound sparing strategy is what keeps etch tools running and matched. Sourcing the Core Inner Electrode through ESCT Fab Support gives fabs a dependable second-source option with clear commercial and operational advantages:
It is the central silicon cathode surface that couples RF power into the plasma over the middle of the wafer, shapes the centre-zone electric field and helps conduct heat away from the wafer support. In short, it sets the baseline conditions for etching the central region of every wafer.
No. ES2099-051 is supplied as a second-source new component that is OEM-compatible with LAM 716-069688-005. It is verified to match the form, fit and function of the original part, but it is not an original OEM part and is not sold as one.
Replacement interval depends on the chemistry, power and duty cycle of your process. As a consumed silicon surface it is changed on a scheduled preventive-maintenance basis once erosion, particle data or process drift indicate the end of its useful life, so most fabs track it against wafer or RF-hour counts.
Typical indicators include drifting centre-to-edge uniformity, etch-rate or profile shift, rising particle or defect counts, visible thinning or cracking, and unstable plasma or RF tuning. Any of these, especially in combination, suggests the electrode is reaching end of life.
The typical lead time is 4–5 weeks. Because this is a recurring consumable, we recommend holding buffer stock aligned to your preventive-maintenance schedule so a worn electrode never delays a chamber return to production.
When the part matches the OEM geometry, silicon specification and contact interface, and is installed correctly and qualified, it should behave equivalently to the original. As with any cathode consumable, we advise running your standard conditioning and qualification routine after installation to confirm uniformity and particle performance before high-volume use.
The Core Inner Electrode (LAM 716-069688-005, ESCT ES2099-051) is the central silicon cathode part that governs RF coupling, centre-zone field geometry and thermal control over the middle of the wafer in 300 mm plasma etch chambers. As a consumed, plasma-facing silicon surface it directly influences uniformity, etch-rate stability, particle performance and tool matching, making it one of the more critical scheduled replacement items in an etch chamber. Offered by ESCT Fab Support as a second-source new component with a 4–5 week lead time, it gives fabs a cost-effective, supply-resilient way to keep their LAM etch tools running on specification.
Disclaimer: This part is supplied by ESCT Fab Support as a new, OEM-compatible second-source component, verified to the form, fit and function of Lam Research part number 716-069688-005. It is not an original OEM part and is not sold as one. It is not manufactured by, endorsed by, or affiliated with Lam Research, and all manufacturer names and part numbers are quoted for identification and compatibility purposes only.
Fill out the form below to request a quote for the part/s you require, making sure to include the OEM part number.
If the part you are looking for is not listed, get in touch and we will try to source it for you through our wide network of partners and suppliers.
We use cookies We use analytics cookies to see how visitors use this site, so we can improve it. They are set only if you accept. Read our Cookie Policy.