OEM P/N:
ESCT P/N:
PART TYPE:
OEM:
The Silicon CEL Inner Electrode is a high-purity silicon consumable that sits within the upper electrode assembly of Tokyo Electron (TEL) 300 mm plasma etch process chambers. In TEL nomenclature, “CEL” denotes the confinement electrode group that surrounds and supports the main silicon electrode plate, and this particular component is the inner member of that group, the “C2” designation and the “TE-T10-P-LABY” reference both point to a labyrinth-profile inner ring carried on the cathode (upper electrode) side of the chamber. The labyrinth geometry is the defining feature: rather than a flat interface, the part presents a stepped, interlocking edge that mates with the adjacent confinement parts to form a tortuous gas path.
Manufactured from semiconductor-grade silicon, the inner electrode is sacrificial by design. It is positioned directly at the boundary of the active plasma, where it shares the same RF potential and chemical environment as the main electrode while shielding the structural metalwork behind it from ion bombardment and fluorine-based chemistries. As a silicon part in a silicon-etch or dielectric-etch environment, it is chosen specifically because its erosion products are chemically benign relative to metal or quartz alternatives, helping keep the wafer environment clean.
Because it governs both the local electric field at the chamber edge and the conductance of process gas leaving the confinement region, the Silicon CEL Inner Electrode has a direct bearing on plasma confinement, edge etch uniformity and particle performance. It is a routinely replaced wear part, and maintaining a verified supply of correctly profiled inner electrodes keeps a fleet of TEL etch chambers matched and productive.
Within the upper electrode stack, the inner CEL electrode performs several interlocking jobs that together stabilise the plasma over the wafer and protect the chamber hardware. Its silicon construction and labyrinth profile are both deliberate, and each contributes to a specific process function:
The performance of any CEL electrode begins with the silicon itself. High-purity, controlled-resistivity silicon is used so that the part presents a predictable electrical character to the RF circuit and so that its erosion products do not introduce metallic contamination onto the wafer. As the surface is exposed to energetic ions and fluorine radicals it erodes uniformly rather than spalling, and the rate of that erosion is one of the key inputs to the chamber’s preventive-maintenance interval.
The labyrinth profile is what distinguishes this inner electrode from a plain ring, and it only works if the part is machined to tight tolerances. The stepped edge must mate precisely with the surrounding confinement components to set the correct gap conductance and to keep the plasma sheath anchored at the intended boundary. Surface finish, step depth and concentricity all influence how the gas path behaves and how evenly the field is presented around the full circumference.
Although it is a relatively small component, the inner CEL electrode influences several of the metrics that fab process engineers watch most closely. A worn, mismatched or incorrectly profiled part propagates straight into wafer results:
The dominant wear mechanism is steady erosion of the silicon surface by ion bombardment and fluorine attack. Over time the labyrinth step rounds off and the part thins, which opens up the confinement gap, alters gas conductance and shifts the edge field. Beyond a certain point the erosion changes the etch profile at the wafer perimeter and the electrode must be replaced to recover the original process window.
Silicon is brittle, and the inner electrode is exposed to repeated thermal cycling and intense RF fields. Localised arcing at the labyrinth gap, a contaminated mating face or a handling-induced micro-crack can all seed a fracture. A cracked electrode generates particles, distorts the local field and can fail abruptly, so any chipping, hairline cracking or arc-burn marks seen at a PM are grounds for immediate replacement.
Process by-products redeposit on the cooler and recessed faces of the labyrinth. As these films thicken they stress, crack and shed flakes that raise particle counts and on-wafer defects. Build-up in the labyrinth channel also degrades the gas path and can promote arcing, which is why deposition state is assessed alongside raw erosion when deciding whether to replace the part.
Replacement is normally carried out during a scheduled preventive-maintenance window with the chamber vented and the upper electrode assembly accessible. Always follow the applicable TEL maintenance procedure and your site’s safety rules; the steps below summarise good practice for a silicon confinement consumable:
Silicon confinement electrodes are consumed on a predictable cadence, so holding verified replacements on the shelf is a core part of any TEL etch fleet’s uptime plan. ESCT Fab Support supplies the Silicon CEL Inner Electrode as a cost-effective, fit-for-purpose alternative to sole-sourcing through the OEM, with the following advantages:
It is the inner member of the confinement electrode (CEL) group within the upper electrode assembly of a TEL 300 mm plasma etch chamber. It defines the inner boundary of the plasma confinement region, carries RF potential to help shape the field at the wafer edge, and its labyrinth step forms a controlled gas path while presenting a sacrificial silicon surface to the plasma.
No. This is supplied as a 2nd-source new part that is verified to the form, fit and function of TEL OEM P/N 3D10-202364-12. It is not an original OEM-branded component, but it is a new, unused part intended as a compatible replacement for that electrode.
It is machined from high-purity, controlled-resistivity semiconductor-grade silicon. This material is chosen so the part presents a predictable electrical character to the RF circuit and so that its erosion products remain chemically compatible with silicon and dielectric etch chemistries, protecting wafer cleanliness.
Replacement is driven by erosion of the silicon and the labyrinth step, by deposition build-up in the gas path, and by any visible cracking, chipping or arc damage found at a PM. As wear opens the confinement gap, you may also see drift in edge uniformity, rising particle counts or RF instability, all of which signal that the electrode has reached the end of its useful life.
The stepped labyrinth forms a tortuous, controlled-conductance gas path that lets neutrals and by-products exit the confinement region while resisting plasma leakage and arcing across the gap. Because it depends on a precise mate with the surrounding CEL parts, the step depth, concentricity and surface finish must be machined to tight tolerances to reproduce the original confinement and gas-flow behaviour.
The part carries ESCT P/N ES7099-009 and corresponds to TEL OEM P/N 3D10-202364-12. Typical lead time is 4–5 weeks, which makes it well suited to planned preventive-maintenance scheduling and safety-stock replenishment rather than emergency-only sourcing.
The Silicon CEL Inner Electrode (TEL OEM P/N 3D10-202364-12, ESCT P/N ES7099-009) is the inner labyrinth-profile confinement electrode in the upper electrode assembly of TEL 300 mm plasma etch chambers. Made from high-purity silicon, it defines the inner edge of the plasma confinement region, helps shape the RF field at the wafer perimeter, forms a controlled gas-conductance path through its labyrinth step and presents a clean sacrificial surface to the plasma. As a consumable subject to erosion, arcing and deposition, it is replaced on a regular PM cadence, and a reliable supply directly supports edge uniformity, particle performance and chamber matching across an etch fleet.
Disclaimer: This part is supplied by ESCT Fab Support as a new, OEM-compatible second-source component, verified to the form, fit and function of Tokyo Electron part number 3D10-202364-12. It is not an original OEM part and is not sold as one. It is not manufactured by, endorsed by, or affiliated with Tokyo Electron, and all manufacturer names and part numbers are quoted for identification and compatibility purposes only.
Fill out the form below to request a quote for the part/s you require, making sure to include the OEM part number.
If the part you are looking for is not listed, get in touch and we will try to source it for you through our wide network of partners and suppliers.