OEM P/N:
ESCT P/N:
PART TYPE:
OEM:
The Ground Electrode Bracket, AMAT P/N 0020-83963, is a precision structural mounting component used within the extraction electrode assembly of Applied Materials ion implanter source and beamline hardware. In an ion implanter, ions generated in the arc chamber are pulled out and accelerated through a stack of electrodes held at carefully controlled potentials. The ground electrode (the final, earth-referenced element of this extraction optics stack) must be located with tight geometric accuracy relative to the plasma electrode and the suppression electrode. This bracket is the rigid mechanical interface that fixes the ground electrode in that position, carries it on the source mounting framework, and maintains the electrode-to-electrode gaps that define beam extraction.
Although it is a passive, non-electronic part, the ground electrode bracket sits at one of the most demanding locations in the tool. It operates under high vacuum, in the immediate vicinity of high extraction voltages, intense ion bombardment, and the elevated radiant heat thrown off by the arc chamber and beam. Any movement, distortion, or contamination of this bracket translates directly into misalignment of the extraction optics, which the implanter sees as unstable beam current, poor transmission, or repeated source faults.
Because the bracket holds the ground (earth-referenced) electrode, it also forms part of the grounding and reference path for the extraction stack. Maintaining a clean, low-resistance mechanical connection between the electrode, the bracket, and the source structure is therefore important not only for alignment but for the predictable electrostatic behaviour of the entire extraction region.
Within the source and beamline, the ground electrode bracket performs several interlocking functions that together govern how cleanly ions are extracted and transported downstream toward the analyser magnet and end station.
As a structural part, the ground electrode bracket is judged almost entirely on its dimensional stability and its ability to hold alignment under load. Its performance depends on how well it resists distortion in a hot, high-vacuum, electrically active environment.
The bracket must hold the ground electrode within tight positional tolerances so that the extraction gaps remain uniform across the aperture. Small shifts in flatness or hole position change the local field geometry and degrade beam optics.
Sitting near the arc chamber and the ion beam, the bracket experiences substantial radiant heating and must remain stable under repeated thermal cycling without outgassing or releasing contaminants into the high-vacuum source region.
Because the bracket fixes the geometry of the final extraction electrode, its condition propagates directly into beam quality and, ultimately, into wafer-level implant uniformity. A degraded or mispositioned bracket shows up as instability that operators often chase elsewhere in the source.
Although a bracket has no moving parts, the punishing environment around the extraction optics drives several recognisable failure patterns over the service life of the source.
Repeated heating from the arc chamber and beam, combined with mechanical clamping loads, can gradually warp the bracket or relax its mounting faces. Even small amounts of bow shift the ground electrode out of its intended position and open or close the extraction gap unevenly.
Sputtered material and process residues build up on surfaces near the beam, while stray ions slowly erode exposed edges. Conductive flaking deposits can bridge gaps and promote arcing, and erosion of contact faces weakens both the mechanical fit and the grounding path.
Thermal cycling can back off fasteners and oxidise or contaminate the bonded contact surfaces. The result is a higher-resistance, intermittent ground connection that destabilises the extraction field and is frequently misread as an electrode or power-supply fault.
Replacement should be carried out by qualified service technicians following the relevant Applied Materials maintenance procedures for the specific source and tool configuration. The sequence below outlines the typical approach for fitting the ground electrode bracket.
Structural source parts such as the ground electrode bracket are easy to overlook in spares planning because they rarely “wear out” in an obvious way, yet a warped or contaminated bracket can be the hidden cause of chronic source instability. Holding a verified replacement on the shelf shortens diagnosis and turns an open-ended troubleshooting exercise into a planned swap.
It is the structural mount that fixes the ground (earth-referenced) electrode in the extraction electrode stack of an AMAT ion implanter source. It holds the electrode in position, sets the electrode-to-electrode gaps and maintains the grounding connection that together define stable beam extraction.
No. This is a new, OEM-compatible replacement part supplied by ESCT Fab Support and verified to the form, fit and function of AMAT P/N 0020-83963. It is not an original OEM part and is not sold as one; it is offered as a compatible alternative for maintenance and repair.
Common indicators include persistent extraction instability, falling beam current, increased high-voltage sparking, or difficulty holding alignment after electrode changes. Visible warping, heavy deposition or eroded contact faces found during source maintenance are strong signs that the bracket should be replaced.
Yes, because it locates the final extraction electrode, the bracket directly influences extraction geometry. A correctly fitted bracket helps restore proper gaps and beam optics, which supports consistent beam current and dose uniformity across the wafer.
The typical lead time is approximately 2.5 weeks. We recommend confirming current availability at the time of order, as stock and demand for source hardware can vary.
It should be installed by trained technicians following the appropriate AMAT maintenance documentation for your source and tool. Correct gap setting, clean grounding surfaces, proper fastener torque and a high-voltage conditioning step after pump-down are all important to a successful replacement.
The Ground Electrode Bracket, AMAT P/N 0020-83963 (ESCT P/N ES227-0012), is a precision structural component that mounts and aligns the ground electrode within the extraction optics of AMAT ion implanter source and beamline systems. Though passive, it is critical to extraction geometry, grounding integrity and beam stability, and its condition feeds directly into beam current, transmission and dose uniformity. Keeping a verified, OEM-compatible bracket on hand allows fabs to address a frequently overlooked source of instability quickly and predictably during planned maintenance.
Disclaimer: This part is supplied by ESCT Fab Support as a new, OEM-compatible second-source component, verified to the form, fit and function of Applied Materials part number 0020-83963. It is not an original OEM part and is not sold as one. It is not manufactured by, endorsed by, or affiliated with Applied Materials, and all manufacturer names and part numbers are quoted for identification and compatibility purposes only.
Fill out the form below to request a quote for the part/s you require, making sure to include the OEM part number.
If the part you are looking for is not listed, get in touch and we will try to source it for you through our wide network of partners and suppliers.