Source Magnet Power Supply

PART DETAILS

9090-00046
Source Magnet Power Supply

OEM P/N: 

9090-00046

ESCT P/N: 

ES3033-146

PART TYPE:

N/A

OEM: 

AMAT
Repair Offered
MORE INFO

Source magnet power supply (OEM P/N 9090-00046), magnet coil power supply for AMAT Quantum / xR-class ion implantation systems

ESCT P/N ES3033-146, form, fit and function replacement for the source magnet drive

The Source Magnet Power Supply is the dedicated current-regulated DC supply that energises the source magnet on Applied Materials (AMAT) Quantum and xR-class ion implanters. In these tools, the ion source produces a plasma from a feed gas, and the extracted ions must be steered, confined and shaped before they travel down the beamline towards the wafer. The source magnet generates the magnetic field that supports this process, and the field strength is set entirely by the regulated current this supply delivers to the magnet coil. Without a stable, accurate magnet current the source cannot maintain a consistent plasma geometry, and the beam that follows it inherits every fluctuation.

Physically, the unit is a high-current, low-voltage power supply built to drive an inductive magnet load rather than a resistive one. It sits within the source power and gas-box section of the implanter, alongside the arc, filament, extraction and bias supplies that together bring the ion source to life. Because the magnet coil is an inductive element with appreciable resistance and substantial stored energy, the supply is engineered to ramp current smoothly, hold it against thermal drift, and clamp the inductive flyback safely whenever the field is reduced or the source is shut down.

For a fab running implant recipes to tight dose and angle tolerances, the magnet supply is one of those quiet components that is invisible when it works and impossible to ignore when it drifts. Beam current stability, source lifetime and even the angle distribution of the extracted ions all depend on the magnet field being exactly where the recipe expects it. That is why this part belongs in every well-managed implanter spares strategy.

Functional role of the source magnet power supply in AMAT implanter platforms

The supply’s job is to convert the tool’s incoming AC or DC bus power into a precisely regulated current that holds the source magnet at the field strength the implant recipe demands. In an ion source, that field shapes and confines the arc plasma, influencing how efficiently ions are produced and how the beam is presented to the extraction optics. Its core functions include:

  • Delivering a regulated, repeatable DC current to the source magnet coil across the full operating range called for by implant recipes.
  • Maintaining current setpoint against changes in coil resistance as the magnet warms during sustained operation.
  • Ramping the magnet field up and down in a controlled manner during source start-up, recipe changes and shutdown.
  • Safely managing the inductive energy stored in the coil, clamping flyback voltages when current is reduced.
  • Reporting current, voltage and fault status back to the source controller for closed-loop regulation and interlocking.
  • Responding to interlocks and shutting down cleanly on over-current, over-temperature or loss-of-load conditions.

Electrical and signal performance

Current regulation and stability

Because magnetic field is proportional to coil current, this supply operates as a current source rather than a voltage source. The control loop continuously measures the actual current through the magnet and adjusts its output to match the commanded setpoint, compensating for the rising resistance of the copper winding as it heats. A well-behaved unit holds its setpoint with low ripple and minimal long-term drift, which translates directly into a stable magnetic field and therefore a stable, repeatable ion beam. Tight regulation under varying thermal load is the single most important electrical characteristic of the part.

  • Closed-loop current regulation referenced to a precision current-sense element.
  • Low output ripple to avoid modulating the magnet field and the resulting beam.
  • Thermal compensation so setpoint holds as the coil resistance changes with temperature.
  • Controlled slew rate during ramps to protect the coil insulation and downstream electronics.

Driving an inductive magnet load

Driving an inductor is fundamentally different from driving a heater or a resistor. The magnet stores energy in its field, so the supply must include freewheeling and clamp circuitry to absorb that energy whenever current is commanded down, preventing damaging voltage spikes across the output devices. The power stage, whether a phase-controlled rectifier or a switch-mode topology, works with smoothing and filtering components to present clean DC to the coil while tolerating the back-EMF the load produces. Hard-wearing protection on the output is what keeps the supply, the coil and the wiring intact through years of ramp cycles.

  • Freewheel and clamp paths to dissipate inductive flyback energy safely.
  • Output filtering sized for the coil’s inductance and the supply’s switching behaviour.
  • Over-current, over-temperature and open-load fault detection with clean shutdown.
  • Galvanic separation and status signalling compatible with the source controller’s interface.

Impact on tool performance and yield

The magnet field set by this supply directly shapes the plasma in the ion source, so any instability propagates straight into the beam and onto the wafer. A drifting or noisy magnet current undermines the very parameters implant recipes are written to control, with measurable consequences for productivity and yield:

  • Beam current fluctuations that disturb dose control and increase wafer-to-wafer variation.
  • Shifts in beam shape or angle that affect implant uniformity across the wafer.
  • Reduced source efficiency and shortened source life from a poorly confined plasma.
  • Tuning instability that lengthens setup time and lowers tool availability.
  • Unplanned source faults and aborts that drive scrap risk and rework.
  • Difficulty qualifying the tool after maintenance if the field cannot be held precisely.

Common failure modes

Output and power-stage degradation

The components that carry the magnet current (rectifiers or switching devices, output diodes and the associated clamp circuitry) endure the highest electrical and thermal stress in the unit. Repeated ramp cycles and the back-EMF of the inductive load gradually fatigue these parts, eventually producing reduced output, current that will not reach setpoint, or hard over-current trips when a device finally fails short.

Regulation drift and control faults

Ageing of the current-sense reference, control-loop components and feedback path causes the supply to hold a slightly wrong current, so the magnet field no longer matches the commanded value. The symptom is often subtle: beams that need re-tuning more frequently, drift over a shift, or a setpoint that the operator can no longer trust. Left unaddressed, this quietly erodes process repeatability.

Thermal and capacitor wear

Cooling fans, heatsinks and electrolytic filter capacitors all age with hours and temperature. Dust-blocked airflow, dried-out capacitors and degraded thermal interfaces raise internal temperatures, increase output ripple and trigger over-temperature shutdowns. These wear-driven failures are the most common reason an otherwise healthy supply begins to misbehave and are a key argument for keeping a tested spare on the shelf.

Installation and replacement guidance

Replacement should be carried out by a qualified service technician following AMAT procedures for the specific implanter, since the magnet supply sits among high-current source-power wiring. The following sequence outlines the general approach:

  • Place the source in a safe state, shut down the tool’s source power and follow lock-out/tag-out before any access.
  • Confirm the magnet coil current has fully decayed and verify the absence of stored energy before disconnecting.
  • Label and disconnect the high-current magnet output leads, the input power connections and the control/status harness.
  • Remove the failed supply from its rack or chassis location, noting orientation, mounting and cooling clearances.
  • Fit the replacement, reconnect all power and signal connections to the correct torque and polarity, and verify cooling airflow.
  • Restore power, ramp the magnet current under controlled conditions and confirm the field reaches setpoint with low ripple and no faults.
  • Re-tune the source as required and run the tool’s qualification checks before returning it to production.

Spare parts strategy for AMAT ion implanters

Source-power supplies are classic single-point-of-failure items: when the magnet supply is down, the source is down, and so is the tool. Holding a verified replacement turns a multi-day OEM lead-time event into a same-shift swap. ESCT Fab Support helps fabs manage exactly this risk:

  • Cross-referenced to AMAT OEM P/N 9090-00046 and stocked under ESCT P/N ES3033-146 for fast identification.
  • Supplied verified to form, fit and function so it drops into the existing source-power location.
  • A cost-effective alternative to sole-source OEM procurement, with shorter typical availability.
  • Supports lifecycle management of ageing Quantum and xR-class implanters where OEM stock is constrained.
  • Backed by technical support to help confirm fit against your specific tool configuration.

Frequently asked questions

What does the source magnet power supply actually do?

It supplies a precisely regulated DC current to the source magnet coil in an AMAT ion implanter. That current sets the magnetic field that confines and shapes the plasma in the ion source, which in turn governs how the ion beam is produced and presented to the extraction optics.

Is this an original OEM part?

No. This is not an original AMAT part. It is supplied as an OEM-compatible replacement that is cross-referenced to AMAT P/N 9090-00046 and verified to match the original in form, fit and function so it can serve as a direct replacement in the source-power section of the tool.

Which tools does it fit?

It is intended for AMAT Quantum and xR-class ion implantation systems that use this magnet supply in their source-power configuration. Because implanters are configured in many variants, we recommend confirming the part against your tool’s specific configuration before ordering, and our team can assist with that check.

How do I know my existing magnet supply has failed?

Typical indicators include the magnet current failing to reach setpoint, over-current or over-temperature trips, increased beam instability requiring frequent re-tuning, and unexpected source faults. Drift that forces more frequent tuning over a shift is a common early warning that the regulation or filtering has degraded.

Why does magnet current stability matter so much?

Magnetic field strength is set by coil current, and that field shapes the source plasma. Any ripple or drift in the current modulates the field and therefore the beam, affecting beam current, shape and uniformity. Stable, repeatable current is what keeps implant dose and angle within recipe tolerance.

Can I install it myself?

Replacement should only be performed by qualified service personnel following AMAT procedures, because the unit handles high-current source-power wiring and an inductive load that stores energy. Proper lock-out/tag-out, verification that the coil has de-energised, correct connections and post-installation qualification all matter.

Summary

The Source Magnet Power Supply (AMAT P/N 9090-00046, ESCT P/N ES3033-146) is the current-regulated DC supply that energises the source magnet on AMAT Quantum and xR-class ion implanters. By holding a stable, accurate current through the magnet coil, it sets the magnetic field that confines the source plasma and underpins beam stability, dose control and source lifetime. Its main wear points are the power stage, the current-regulation electronics and the thermal and capacitor components, all of which make it a sensible item to hold as a tested spare. ESCT Fab Support offers this part verified to form, fit and function to keep ageing implanters running with minimal downtime.

Disclaimer: This part is supplied by ESCT Fab Support as a new, OEM-compatible second-source component, verified to the form, fit and function of Applied Materials part number 9090-00046. It is not an original OEM part and is not sold as one. It is not manufactured by, endorsed by, or affiliated with Applied Materials, and all manufacturer names and part numbers are quoted for identification and compatibility purposes only.

REQUEST A QUOTE

Fill out the form below to request a quote for the part/s you require, making sure to include the OEM part number.

If the part you are looking for is not listed, get in touch and we will try to source it for you through our wide network of partners and suppliers.