OEM P/N:
ESCT P/N:
PART TYPE:
OEM:
The Source Magnet Power Supply (Source MAG PSU), AMAT OEM P/N 1140-90056, is the regulated DC supply that energises the source magnet coil within the ion source region of Applied Materials Quantum and xR-class ion implantation systems. In these implanters the arc discharge that produces the ion plasma sits inside a magnetic field generated by the source magnet. By driving a precisely controlled current through that coil, the Source MAG PSU sets the strength of the confining field, which in turn governs plasma density, arc stability and the efficiency with which dopant ions are produced and presented to the extraction optics.
Although it is physically a power-electronics chassis rather than a part exposed to the beamline vacuum, the Source MAG PSU has an outsized influence on the front end of the tool. The magnetic field it sustains determines how electrons are confined within the arc chamber, how readily the source strikes and holds an arc, and how uniformly ions are extracted. A drifting, noisy or current-limited magnet supply translates directly into unstable beam current, poor source life and recurring extraction faults, symptoms that are easily mis-attributed to the source itself.
Because the magnet current is a tightly controlled set point referenced by the implanter’s recipe and source control software, the Source MAG PSU must deliver low-ripple, repeatable output across a wide load range while tolerating the thermal and electrical environment of the source terminal. ESCT supplies this unit as a tested, form-fit-and-function equivalent to keep the source subsystem running without committing to OEM lead times or pricing.
Within the source subsystem, the Source MAG PSU performs several interlocking jobs that together keep the ion source operating in its intended regime:
The magnet coil is a largely inductive load, so the supply must drive current into a winding whose resistance rises as it heats. Effective regulation means the Source MAG PSU continuously trims its output to hold the commanded current despite this changing load, keeping the magnetic field, and the confined plasma, constant.
Beyond raw power delivery, the unit must integrate cleanly with the implanter’s source control electronics, accepting a current command and returning trustworthy feedback while protecting itself and the coil under fault conditions.
Because the magnet field shapes the plasma that the entire beamline draws from, the condition of the Source MAG PSU propagates downstream into productivity and device results:
Ageing electrolytic capacitors, degraded feedback components and stressed power semiconductors gradually erode regulation, allowing the magnet current to drift away from set point or carry excess ripple. The result is a creeping loss of beam stability that often appears long before any fault is logged.
Continuous current delivery into an inductive load generates heat in the power stage, rectifiers and magnetics. Blocked airflow, failed fans, dried thermal interfaces or fatigued solder joints lead to over-temperature trips or outright destruction of switching devices, frequently presenting as repeated thermal shutdowns under sustained load.
High-current output terminals, source-terminal connectors and control harnesses are subject to vibration, thermal cycling and the corrosive source environment. Loose or oxidised connections raise resistance, generate heat and produce intermittent over-current or loss-of-regulation faults that can be hard to distinguish from coil or source-head problems.
Replacement should be carried out by a qualified implant service engineer following Applied Materials safety and lockout procedures. The magnet supply and its terminals can carry hazardous voltages and currents, and the source region demands disciplined energy isolation. The following sequence outlines a typical workflow:
Source-region power supplies are exactly the kind of low-redundancy, high-impact component that warrants a planned spares position rather than reactive sourcing. ESCT supports fab maintenance teams with an alternative to OEM channels for the Source MAG PSU:
It drives a regulated DC current through the ion source magnet coil, setting the magnetic field that confines the arc plasma. That field strength controls plasma density and arc stability, which directly affect how much beam current the source produces and how stable it remains.
No. This is supplied as a new, OEM-compatible part cross-referenced to AMAT P/N 1140-90056 and verified to form, fit and function. It is not an original OEM-branded item, and any OEM part numbers are quoted purely for identification and compatibility.
Common warning signs are slow beam-current drift, difficulty holding a stable arc, magnet-current readback that no longer matches the set point, repeated over-temperature or over-current trips, and intermittent source faults that re-tuning does not resolve. Checking the supply’s current and feedback against specification helps confirm it.
Yes. Ripple or noise on the magnet current modulates the confining field, which can modulate the extracted beam current. In dose-sensitive implants this can show up as degraded uniformity or unstable tuning, so low-ripple regulation matters to device results, not just to tool stability.
The unit is intended for AMAT Quantum and xR-class ion implantation systems that use OEM P/N 1140-90056 in the source magnet supply position. Because source configurations vary, confirm the existing part number and connector arrangement against your tool before ordering, and our team can help verify compatibility.
For most fabs, yes. The magnet supply is a low-redundancy item whose failure idles the source and therefore the whole implanter. Holding a verified spare on the shelf turns a potential multi-day outage into a planned swap measured in hours.
The Source Magnet Power Supply (AMAT OEM P/N 1140-90056, ESCT P/N ES3033-138) is the regulated DC current source for the ion source magnet coil in AMAT Quantum and xR-class implanters. By holding the confining magnetic field steady, it underpins arc stability, beam-current repeatability and dose uniformity at the front end of the tool. Regulation drift, ripple, thermal stress and connector faults are its main failure modes, and because it sits at a low-redundancy point in the source subsystem, a tested replacement is a sound critical spare. ESCT supplies this unit verified to form, fit and function as a cost-effective, readily available alternative to OEM sourcing.
Disclaimer: This part is supplied by ESCT Fab Support as a new, OEM-compatible second-source component, verified to the form, fit and function of Applied Materials part number 1140-90056. It is not an original OEM part and is not sold as one. It is not manufactured by, endorsed by, or affiliated with Applied Materials, and all manufacturer names and part numbers are quoted for identification and compatibility purposes only.
Fill out the form below to request a quote for the part/s you require, making sure to include the OEM part number.
If the part you are looking for is not listed, get in touch and we will try to source it for you through our wide network of partners and suppliers.