Magnet Power Supply

PART DETAILS

0090-90353
Magnet Power Supply

OEM P/N: 

0090-90353

ESCT P/N: 

ES3033-139

PART TYPE:

N/A

OEM: 

AMAT
Repair Offered
MORE INFO

Magnet power supply (OEM P/N 0090-90353), beamline magnet coil drive for AMAT Quantum / xR-class ion implantation systems

ESCT P/N ES3033-139, high-current regulated DC supply for analysing magnet coils

The Magnet Power Supply (AMAT OEM P/N 0090-90353) is the regulated high-current DC source that energises the electromagnet coils in an Applied Materials ion implanter beamline. On Quantum and xR-class implanters, the analysing (mass-resolving) magnet bends the extracted ion beam through a fixed radius so only ions of the desired mass-to-charge ratio reach the resolving aperture. That field is set by the current this supply delivers to the windings, making the unit a primary determinant of beam purity and dose accuracy.

Physically, it is a rack- or cabinet-mounted assembly that converts facility three-phase AC into a controlled DC output sourcing tens to hundreds of amperes into a low-resistance, highly inductive load. As a closed-loop current regulator, it trims the output to hold the set-point despite coil heating, line variation and load drift.

Because magnetic rigidity depends directly on field strength, small drifts in coil current shift the beam at the aperture and degrade species selection. The supply therefore sits at the heart of beam tuning and dose integrity, and a stable unit gives repeatable results across wafers and lots.

Functional role of the magnet power supply in AMAT ion implanter platforms

Within the beamline, the supply is the interface between facility power and the magnet coil, translating a field demand from the control system into regulated current. Its core responsibilities include:

  • Converting three-phase AC into high-current regulated DC for the analysing magnet coils.
  • Holding coil current to set-point so the field, and therefore mass selection, stays constant.
  • Ramping to new set-points at recipe and species transitions at rates suited to the inductance.
  • Providing closed-loop regulation, compensating for coil heating and line variation.
  • Reporting readback current and fault status for interlock and beam-tune use.
  • Protecting itself and the magnet through over-current, over-temperature and load-loss interlocks.

Electrical and signal performance

Output regulation and stability

The defining characteristic of a magnet supply is its current regulation. The coil resistance rises as the windings warm, so an unregulated source would let current, and field, drift. This unit holds a flat output through a precision feedback loop.

  • Tight current regulation against line and load variation throughout long implants.
  • Low output ripple so the resolved beam position stays steady.
  • Controlled ramp and settling, with accurate readback the beam tune can trust.

Power conversion and thermal management

Delivering large DC currents into a low-resistance load dissipates substantial heat, so the supply depends on solid power semiconductors and effective cooling.

  • High-current rectifier and regulator stages rated for continuous duty at full output.
  • Forced-air or liquid cooling and heatsinks sized to remove conduction and switching losses.
  • Bulk filter capacitors, DC bus and heavy-gauge bus-work that carry high current without excessive drop.

Impact on tool performance and yield

Because the analysing magnet field isolates the wanted species, the stability of this supply propagates into wafer-level results. A degraded unit appears as:

  • Beam drift at the resolving aperture, losing transmitted current and destabilising dose.
  • Species contamination if the field no longer separates the target mass cleanly.
  • Recipe irreproducibility, the same demand yielding a different beam day to day.
  • Aborted runs and lost availability while the supply is diagnosed and replaced.

Common failure modes

Power semiconductor and rectifier failure

The rectifier and regulating semiconductors endure continuous high current and thermal cycling. Junction fatigue, solder-joint degradation or a cooling shortfall can cause a device to fail short or open, producing loss of output or an over-current trip on beam demand.

Regulation drift and control loop faults

Ageing reference components, a drifting transducer, or degraded feedback circuitry let the current wander from its set-point. The symptom is subtle, the supply still runs, but the field is no longer where the readback claims, so the beam tune walks off and dose repeatability suffers before any hard fault.

Thermal and capacitor degradation

Clogged filters, failing fans, restricted coolant flow or dried-out capacitors raise internal temperatures and increase ripple. This often shows first as intermittent over-temperature trips, added noise on the magnet current, or shutdowns under high output.

Installation and replacement guidance

Replacement should be carried out by a qualified technician following the AMAT service documentation. As this is a high-current, high-stored-energy assembly driving an inductive load, lock-out and discharge steps are critical. A typical sequence is:

  • Place the implanter in a safe state, disable beam and isolate the magnet circuit.
  • Lock out the AC feed and let the DC bus and filter capacitors discharge fully.
  • Label and disconnect the output bus to the coil, the AC input and the control harnesses.
  • Remove the supply from its rack, supporting its weight, noting all connection orientations.
  • Install the replacement (ES3033-139) to the correct torque and polarity.
  • Restore power, clear faults, verify cooling, then ramp the current and confirm regulation and readback.
  • Re-run the beam tune and confirm species selection before returning to production.

Spare parts strategy for AMAT ion implanter power supplies

A magnet supply failure idles the entire beamline, so a verified shelf spare is a high-value decision. ESCT Fab Support helps implant teams keep these long-lead, high-cost assemblies available:

  • Form, fit and function cross-reference to AMAT OEM P/N 0090-90353 under ESCT P/N ES3033-139.
  • Support for Quantum and xR-class beamline configurations.
  • Output regulation and readback verified before despatch.
  • A cost-effective alternative to sole-source OEM procurement for ageing platforms.
  • Knowledgeable support to confirm compatibility against your tool revision.

Frequently asked questions

What does the magnet power supply actually do?

It supplies regulated high-current DC to the analysing magnet coils. That current sets the field that bends the beam and selects the desired species at the aperture, so it directly governs beam purity and dose stability.

Is this an original AMAT OEM part?

No. It is supplied by ESCT Fab Support as a new, OEM-compatible part cross-referenced to AMAT P/N 0090-90353 and verified to match in form, fit and function. It is not an original AMAT OEM unit.

Which systems is it used on?

It is intended for AMAT Quantum and xR-class implanters where it drives the analysing magnet. Because configurations vary by tool revision, confirm compatibility before ordering.

How do I know if my supply is failing rather than the magnet?

Typical supply-side symptoms are readback that disagrees with demand, over-current or over-temperature trips, an unstable beam tune, and increased ripple. Confirming the coil resistance and insulation are within spec helps separate a supply fault from a magnet one.

What safety precautions matter during replacement?

This is a high-current assembly driving a large inductance with substantial stored energy. Lock out the AC feed, allow the DC bus and filter capacitors to discharge, and follow the AMAT procedure. The inductive load can generate hazardous voltages if disconnected while energised.

Should I keep one as a spare?

Yes. A magnet supply fault stops the beamline entirely and these units can carry long lead times, so a verified spare protects tool availability.

Summary

The Magnet Power Supply (AMAT OEM P/N 0090-90353, ESCT P/N ES3033-139) is the regulated high-current DC source that energises the analysing magnet on AMAT Quantum and xR-class implanters. By holding coil current, and therefore the bending field, at its set-point, it determines species selection, beam stability and dose repeatability. Its main risks are power-semiconductor failure, regulation drift and thermal or capacitor degradation. A verified, form-fit-function replacement from ESCT Fab Support keeps this critical asset available and protects implant yield and uptime.

Disclaimer: This part is supplied by ESCT Fab Support as a new, OEM-compatible second-source component, verified to the form, fit and function of Applied Materials part number 0090-90353. It is not an original OEM part and is not sold as one. It is not manufactured by, endorsed by, or affiliated with Applied Materials, and all manufacturer names and part numbers are quoted for identification and compatibility purposes only.

REQUEST A QUOTE

Fill out the form below to request a quote for the part/s you require, making sure to include the OEM part number.

If the part you are looking for is not listed, get in touch and we will try to source it for you through our wide network of partners and suppliers.